Tread width | 1000 | 800 | |||
Middle span | 6000 | 10000 | 6000 | 10000 | |
Reaction force (KN) |
R1 | 40 | 38 | 35 | 34 |
R2 | 34.5 | 34 | 32 | 31 | |
R3 | 62.5 | 78.5 | 52 | 64.5 | |
R4 | 63.5 | 79.4 | 54 | 66.6 | |
R5 | 48 | 79.4 | 40 | 66.6 | |
Motor power/Rated current | Conveying length L | Conveying length L | |||
10000~70000 | 8KW/18A | 10000~80000 | 8KW/18A | ||
70001~110000 | 11KW/25A | 80001~110000 | 11KW/25A |
Technical specification | ||
Inclination α | 0-6 o | |
Speed V | 0.5m/s | |
Pedal type | Aluminium alloy (Indoor/Half-outdoor/Outdoor) | |
Pedal width A | 1000 | 800 |
Center distance of handrail band | 1238 | 1038 |
The width of the shape | 1600 | 1400 |
The length of the bearing beam | ≥1660 | ≥1460 |
Installation occasion/Driving mode | The length of L1 | |
Indoor/Star triple | 4000 | 4000 |
Indoor/Frequency conversion | ||
Half-outdoor/Star triple | 4600 | |
Half-outdoor/Frequency conversion | 4600 | |
Outdoor/Star triple | 4000 | |
Outdoor/Frequency conversion | 4600 | |
Power supply | When the moving walk starts under user's 380VAC 50Hz three-phase five-wire power supply system, the decline of voltage is less than or equal to ten percent. Normally, the decline of the running voltage of moving walk is less than or equal to five percent, the max starting current shall be less than the three point five times of rated current. |
Standard Function | |
Static electricity | Over-load protection |
Emergency stop button | Step sagging protection |
Skirting protection | Broken step chain protection |
Handrail entry safety protection | Handrail speed and broken handrail monitor |
Main drive chains safety protection | Skirting anti-clamp device |
Over-speed protection | Step missing detection |
Under-speed protection | The brake opens the monitor switch |
Un-international reversal protection | Handwheel and handwheel protection cover open safety |
Lack of phase, error phase protection | Floor-plate monitor switch |
Short circuit protection | Monitor of brake distance |
Optional function | |
Additional brake | Remote monitoring |
Start, fault alarm warning | Under-speed protection |
Apron board safety brush | Arm lighting system |
Variable frequency energy saving control | Direction of the movement of the escalator |
Automatic start up |